Review




Structured Review

BioMimetic Therapeutics array chip (ibac)
Array Chip (Ibac), supplied by BioMimetic Therapeutics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+chip+%28ibac%29/pmc10924370-222-4-3?v=BioMimetic+Therapeutics
Average 90 stars, based on 1 article reviews
array chip (ibac) - by Bioz Stars, 2026-07
90/100 stars

Images



Similar Products

90
BioMimetic Therapeutics array chip (ibac)
Array Chip (Ibac), supplied by BioMimetic Therapeutics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+chip+%28ibac%29/pmc10924370-222-4-3?v=BioMimetic+Therapeutics
Average 90 stars, based on 1 article reviews
array chip (ibac) - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
BioMimetic Therapeutics integrated biomimetic array chip (ibac)
hRPTECs model on the <t>integrated</t> <t>biomimetic</t> array chip <t>(iBAC).</t> ( A ) Picture of an integrated biomimetic array chip containing 24 units. ( B ) Schematic exploded view of a unit on the iBAC. ( C ) Diagram showing the hRPTECs cultured on the iBAC. ( D , E ) Immunofluorescence micrographs of the hRPTECs and HK2 cells cultured on the iBAC for 4 days labeled with acetylated tubulin (apical), villin (apical) and Na/K-ATPase (basolateral), (bar, 100 µm). ( F ) The coverage rate of the acetylated tubulin, villin and Na/K-ATPase on the hRPTECs and HK2 cells cultured on the iBAC on day 4. ** p < 0.01, *** p < 0.001, **** p < 0.0001.
Integrated Biomimetic Array Chip (Ibac), supplied by BioMimetic Therapeutics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+chip+%28ibac%29/pmc09496563-165-13-13?v=BioMimetic+Therapeutics
Average 90 stars, based on 1 article reviews
integrated biomimetic array chip (ibac) - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

Image Search Results


hRPTECs model on the integrated biomimetic array chip (iBAC). ( A ) Picture of an integrated biomimetic array chip containing 24 units. ( B ) Schematic exploded view of a unit on the iBAC. ( C ) Diagram showing the hRPTECs cultured on the iBAC. ( D , E ) Immunofluorescence micrographs of the hRPTECs and HK2 cells cultured on the iBAC for 4 days labeled with acetylated tubulin (apical), villin (apical) and Na/K-ATPase (basolateral), (bar, 100 µm). ( F ) The coverage rate of the acetylated tubulin, villin and Na/K-ATPase on the hRPTECs and HK2 cells cultured on the iBAC on day 4. ** p < 0.01, *** p < 0.001, **** p < 0.0001.

Journal: Biosensors

Article Title: Functional Evaluation and Nephrotoxicity Assessment of Human Renal Proximal Tubule Cells on a Chip

doi: 10.3390/bios12090718

Figure Lengend Snippet: hRPTECs model on the integrated biomimetic array chip (iBAC). ( A ) Picture of an integrated biomimetic array chip containing 24 units. ( B ) Schematic exploded view of a unit on the iBAC. ( C ) Diagram showing the hRPTECs cultured on the iBAC. ( D , E ) Immunofluorescence micrographs of the hRPTECs and HK2 cells cultured on the iBAC for 4 days labeled with acetylated tubulin (apical), villin (apical) and Na/K-ATPase (basolateral), (bar, 100 µm). ( F ) The coverage rate of the acetylated tubulin, villin and Na/K-ATPase on the hRPTECs and HK2 cells cultured on the iBAC on day 4. ** p < 0.01, *** p < 0.001, **** p < 0.0001.

Article Snippet: In this study, we constructed a renal proximal tubule model on an integrated biomimetic array chip (iBAC) driven by bidirectional shaking, and systematically compared the cell growth, barrier function, transporter expression and drug toxicity of the hRPTECs on the iBAC and the static Transwell.

Techniques: Cell Culture, Immunofluorescence, Labeling